XinleScissor fork electric elevatorWhat is the industrial form

announcer:hp935HP175192871 release time:2024-04-19 10:50:26

For customers to use and operate the lifting platform for a long time, the editor briefly introduces how to maintain and repair the lifting platform: First of all,XinleSubminiature electric elevator, normal maintenance is mainly focused on prevention, resulting in costly repairs.

To ensure safe and reliable braking of the lifting platform and prevent accidents, a hydraulic control one-way valve, also known as a hydraulic lock, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB1&flash; The rotation of the SB6 motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease, and; Program adjustment time delay to avoid frequent movement of electric elevators that may affect their service life.

Xinle.Try to use this equipment in areas with wind force less than level five,XinleElectric mobile hydraulic elevator, and avoid using it when the wind force is too strong to avoid accidents.

The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.

.During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

Installation and dismantling personnel and drivers should hold certificates to work.

Installation and dismantling personnel and drivers should hold certificates to work.


XinleScissor fork electric elevatorWhat is the industrial form



The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements otherwise protective measures shall be taken.

The pressure joint between the pipe joint and the rubber hose fails prematurely, causing oil leakage or pipe explosion. The oil temperature rises due to frequent action of the overflow valve.

The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

offer.The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness, strength, etc. and the production should meet the design requirements.


XinleScissor fork electric elevatorWhat is the industrial form



From the above comparison, it can be seen that hydraulic electric lifting mechanisms have stable lifting, low noise long service life, large load bearing capacity, and are relatively simple, making them suitable for use in stage equipment.

Superior quality.Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

When adding hydraulic oil, it is also necessary to pay attention to the structure of the oil cylinder. Some oil cylinders are relatively complex internally, and how many lifting operations need to be carried out during filling to fully fill each position of the hydraulic oil. Therefore,XinleElectric background axis elevator, when filling, try to add as much as possible, and then test and run the machine empty to see if it reaches the rated position.

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.

Xinle.News Abstract: The development of the lifting platform industry will continue to grow in recent years! With the continuous development of electric lifting machinery for high-altitude operations in recent years, the products of electric lifting platform vehicles have been continuously improved, and various new technologies and materials have emerged, making the further development of lifting platform vehicles possible.

The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.