GansuFolding electric elevatorHow to perform maintenance during the season

announcer:hp935HP175192871 release time:2024-04-18 12:39:55

GansuFixed electric hydraulic elevator,

Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).

Pipeline rupture valve: When the hydraulic system pipeline ruptures and the car stalls and descends, it can automatically cut off the oil circuit and stop descent

Gansu.Fully autonomous lifting is widely used in various high-altitude work fields,GansuElectric elevator small, such as factory maintenance, airport maintenance, street light maintenance, and so on; How to use electric elevators correctly to extend the service life of the equipment and be flexible

Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors, wiring, and oil cylinder once a week to avoid dust and debris affecting normal operation.

.When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test it worked normally.

Installation and dismantling personnel and drivers should hold certificates to work.

The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, etc.

Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

Work courses.When the door is closed,GansuElectric background axis elevator, except for the gap between the lower part of the door that should not exceed 35mm, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.


GansuFolding electric elevatorHow to perform maintenance during the season



Double layer steel mesh: The diameter of the steel bars is 12mm, with a spacing of 200mm.

Project scope.Protective measures should comply with regulatory requirements.

The down travel (limit) switch should be of the automatic reset type.

Setting requirements: The installation and dismantling workers, electricians, and other operators of construction electric elevators should have special construction operations.

Gansu.Low power consumption: When the hydraulic guide rail lifting platform descends, it is driven by the pressure generated by its own weight, greatly saving energy and reducing consumption.

Electric elevators used in various places.

The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.