Albany315 KVA oil immersed transformerPublish Operation Guide

announcer:hp122HP117294921 release time:2024-04-15 10:41:31

On load commissioning:

Brief introduction of zero line of power transformer

Albany.Protection mode for type selection of dry-type test transformer

Before and after sampling, clean the periphery of the sampling port with clean or hairless linen.

.If the power transformer stops running for more than 72h (if the allowable time should be reduced when the ambient humidity is & amp; gt; 95%), it should be insulated before putting into use,Albany10kV dry type transformer test,AlbanyOil immersed box transformer, and accurately measured with a 2500V grounding megger. The insulation resistance from the primary side to the secondary side and the ground should be ^ 300mfl, the insulation resistance from the secondary side to the ground should be ^ 100mh, and the insulation resistance from the iron core to the ground should be & amp; gt; 5mfl (note that the grounding device piece should be removed).

Dry type transformer factory

Oil leakage at looper flange


Albany315 KVA oil immersed transformerPublish Operation Guide



The capacity and working voltage are different. The dry-type transformer is generally suitable for distribution equipment. The capacity is generally below 2000kVA and the working voltage is below 35KV, which also ensures the rated voltage of 110kV; Oil immersed transformers are generally suitable for distribution equipment.

The dry-type transformer used for power plant voltage transformation is different from the oil transformer. It is strictly prohibited to lead the way at the bottom voltage side to prevent the insulation layer of the dry-type transformer from penetrating due to overvoltage caused by overvoltage at the power grid side or lightning stroke on the line.

In the electric field of the winding to the yoke, there must be a strong line breaking component, so that sliding flash charge and discharge may occur at a lower current. In order to better solve this disadvantage,Albany50 kV box type transformer, the appearance of the insulating parts between the winding and the iron yoke should be the same as that of the medium horizontal plane of the winding to the iron yoke insulation as far as possible, so as to reduce the electric field component intersecting with the insulating parts.

High value.Manufacturing process and steps of dry-type transformer

For the installation of lightning rod, it is very easy to damage the relay protection inside and outside of dry-type transformer by lightning. If it is a serious situation, it is very easy to cause fire accidents, power failure, damage to machinery and equipment, etc.

When we apply oil immersed transformer, we all know that it works with the help of oil. What if the oil immersed transformer is on fire? What countermeasures should we do?


Albany315 KVA oil immersed transformerPublish Operation Guide



Power transformers are used in all walks of life

Good reputation.The tail end of the high-voltage winding head and the middle tap are made of copper inserts and embedded parts, with good strength and stiffness, which is conducive to adjusting the data and has a unique and neat style.

During the operation of the transformer, the resistance value of the grounding wire shall be measured accurately every two years.

Power transformer

Albany.Sound in case of phase failure

Deterioration damage of transformer core insulation

Common problems of tap changer of power transformer