BusiaElectric self-propelled elevatorVigorously advocate the maintenance of order

announcer:hp935HP175192871 release time:2024-04-12 10:21:22

Installation verticality deviation guide rail frame erection height, h/mH≤ 7070100150H& gt; 200 verticality deviation/mm≤ (1/100h≤ 70≤ 90≤ 110≤ 130 pairs of steel wire rope construction electric elevators, the verticality deviation of the guide rail frame should not exceed (5/1000) h.

Implementing multiple shifts of homework should fill in and submit records according to regulations.

Busia.Alarm devices can be divided into fixed and mobile platforms, rail type and scissor type (curved arm type) to distinguish between overload or equipment malfunction. Fixed types include: scissor lift cargo elevator chain electric elevator, and installation

Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

.Monthly maintenance and inspection of hydraulic lifting platform rollers, intermediate shafts and bearings, boom hinge shafts and bearings for wear. Add some oil to each part to extend the service life of the lifting platform bearings. The quality and level of hydraulic oil. The lifting platform should be raised throughout the entire process, and at this position, sticky, or has foreign objects such as gravel, it should be replaced in a timely manner (32 # hydraulic oil). Annual maintenance and inspection of all hydraulic pipelines and joints of the lifting platform. The pipeline must not be damaged, and the joints must not be loose. All joints must be tightened. Remove and disassemble the lowering valve of the lifting platform, blow out the plunger with compressed air, then install it and reinstall it. Drain and discard the hydraulic oil, tighten the joint, remove the oil filter, clean it with compressed air, and then return it to the oil tank and connect the pipeline.

The L distance depends on the selected wall mount model.

Safety grounding device. In order to protect against electrical equipment. The metal casing of electrical equipment and the metal structure of electric elevators should be equipped with a safety grounding device. The grounding wire should operate multiple wires, and the neutral wire should not be arbitrarily held as a safety grounding wire. Its grounding resistance should not exceed 4 ohms; The power supply of the electric elevator can be cut off.


BusiaElectric self-propelled elevatorVigorously advocate the maintenance of order



The landing door should be in a normally closed state. Without the permission of the construction electric elevator driver, the landing door shall not be opened.

The movement of its related components is direct.

Installation verticality deviation guide rail frame erection height, h/mH≤ 7070100150H& gt; 200 verticality deviation/mm≤ (1/100h≤ 70≤ 90≤ 110≤ 130 pairs of steel wire rope construction electric elevators, the verticality deviation of the guide rail frame should not exceed (5/1000) h.

index.Speed limit wire rope switch. When the speed limit wire rope trips or breaks. Make the electric elevator unable to start.

As a material loading and unloading equipment recognized by customers in the lifting platform, the guide rail hydraulic lifting platform is superior in terms of product,BusiaPortable electric elevator, civil engineering and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load, can achieve multiple points, and can be controlled up and down floors to achieve safe use.

High lifting height, using side mounted oil cylinders, stable operation, noise free, easy maintenance, and longer service life.


BusiaElectric self-propelled elevatorVigorously advocate the maintenance of order



The entrance of each landing platform must be equipped with a landing door,BusiaElectric belt elevator, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.

Discount.Double layer steel mesh: The diameter of the steel bars is 12mm, with a spacing of 200mm.

That's all for a brief introduction to the common types of electric elevators. I hope everyone can have a better understanding of this product. Currently this product is selling well in China, as many places need to use this type of product that has both lifting function and flexible movement. Companies specializing in producing this type of product are now promoting it on a large scale through the internet, Friends in need can directly find the corresponding companies on the internet and have a brief understanding of the models, performance, the door may not meet the above requirements, but safety should be maintained.

Busia.Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness, strength, stability, etc., and the production should meet the design requirements.

The use of standard section connecting bolts should comply with the user manual and specification requirements.

Use floor doors and cage door devices on construction sites where conditions permit.