NeustadtHydraulic lifting platform experimentProblems that need to be paid attention to in construction

announcer:hp530HP141750488 release time:2024-03-30 12:22:22

Users should arrange dedicated personnel to operate hydraulic elevators, formulate usage details and safety precautions for hydraulic elevators based on their own situation, and hang them on the

The hydraulic pump produces noise. When the hydraulic elevator rises, the hydraulic pump runs at high speed. If there is a problem with the gears or bearings of the hydraulic pump, which causes periodic changes in the hydraulic system pressure, it will also cause resonance in the hydraulic system and generate noise.

Neustadt.Hydraulic cargo elevator sinking refers to the lifting of the cargo elevator equipment to a designated position, and after a period of time, the entire table surface will automatically descend by a certain distance under its own weight. The phenomenon of hydraulic cargo elevators naturally descending during the leveling process. such

The elevator itself has a simple structure and is easy to maintain, which has been favored by a large number of enterprises and individual customers. Hydraulic elevator is a multifunctional heavy loading and unloading mechanical equipment. The lifting system of hydraulic elevators is driven by hydraulic pressure,NeustadtFixed hydraulic lifting platform, also known as hydraulic powered elevators.

.Reason: Manual pump and gear pump have severe oil leakage. Cleaning method: Replace the oil pump sealing ring to clean it. Reason: Gear pump is damaged, The oil pumped out has no pressure. Cleaning method: Replace the gear pump to clean the problem. Reason: Lack of hydraulic oil. Cleaning method: Add enough hydraulic oil to clean the problem. Reason: Circuit open. Cleaning method: Check the button and fuse to clean the problem. Reason: Filter blockage. Cleaning method: Replace or clean the problem. Reason: Support valve or electromagnetic directional valve malfunction. There are two situations: the input voltage of the electromagnetic coil is lack of 220V. The solenoid coil is burnt out and the valve core is stuck. Cleaning method: maintenance or replacement can be used to clean the natural descent of the lifting platform. Reason and cleaning method: one-way valve leakage cleaning method: check the check valve in the valve. Assuming there is dirt on the sealing surface of the check valve. Clean the check valve.

Motor not running: Check all components of the motor for damage and check if there are any problems with the circuit and wiring.

Therefore, in the hydraulic pipeline assembly line, it is necessary to avoid dead bends as much as possible and check the tightness of the sleeve in a timely manner.


NeustadtHydraulic lifting platform experimentProblems that need to be paid attention to in construction



Optional configuration of fixed lifting platform: The fixed lifting platform can be equipped with auxiliary devices according to usage requirements, and can be combined in any combination, such as the safety protection device of the fixed lifting platform; Electrical methods; Form of work platform; Power form, etc. The correct selection of various configurations maximizes the functionality of the lifting platform and achieves effective use.

Hydraulic elevators and load-bearing oil cylinders can directly act on the foundation pit, requiring low shaft strength, and brick or brick concrete structure shafts.

There are many reasons for unstable workbench descent,NeustadtManufacturer of scissor lift, such as overload, severe eccentric load, hydraulic oil impurities, etc. In response to the above reasons, it can be solved by reducing the load, adjusting the center of gravity of the load, and replacing hydraulic oil wholesale for hydraulic cargo elevators.

Sincere service.Voltage too low: Measure the starter voltage, with an allowable fluctuation range of± 10%.

The undercut length of the weld mm should not exceed 10% of the weld seam, frequent inspections and maintenance should be carried out, which not only extends the service life of the hydraulic elevator, but also enables it to exert greater power during operation. Of course, hydraulic elevators also have their own regular repair times and protection methods: regular protection (carried out per shift).


NeustadtHydraulic lifting platform experimentProblems that need to be paid attention to in construction



Voltage too low: Measure the starter voltage with an allowable fluctuation range of± 10%.

Quality inspection report.The installation personnel should confirm and count the equipment details, confirm that there are no omissions in the shipped equipment details, check if the tools are complete, and ensure the smooth progress of the installation process.

There is a possibility of hydraulic system leakage. Check the hydraulic system for leaks, with a focus on checking the hydraulic pipes and joints,NeustadtMobile hydraulic lifting platform/lifting platform, oil cylinders and hydraulic valve connections. If hydraulic oil leaks, replace them with composite pads or disturb unprocessed raw materials.

When placing materials on the platform, they should be placed in the middle of the platform as much as possible. The weight of the goods should be within the standard load range of the equipment, materials and lifting platforms may be injured and dangerous accidents may occur. High priced and various specifications of elevator manufacturers provide timely supply with high cost-effectiveness, and have become the preferred brand for many wire products. Welcome to purchase!

Neustadt.Electrical equipment or component failures. Hydraulic elevator manufacturers tell you that the main reasons for high noise generated by electric motors are: bent or severely worn motor rotors, or damaged bearings, which cause electric motors to sweep and produce noise; The cooling fan of the electric motor is damaged or not firmly fixed, resulting in high noise; The electric motor is not firmly fixed and can also cause vibration, producing high noise.

Volume speed control circuit: Speed control is achieved by adjusting the displacement of a variable pump or variable motor.

Voltage too low: Measure the starter voltage, with an allowable fluctuation range of± 10%.