Ostrovinka5 meter electric spiral elevatorConcentrated competition in the industry

announcer:hp935HP175192871 release time:2024-03-29 10:06:18

Secondly, for the replacement of hydraulic oil on the lifting platform,OstrovinkaFloor electric elevator, it can be replaced once a year. The hydraulic oil must be clean, and after changing the hydraulic oil, it must be automatically lifted and lowered 2 to 3 times to ensure that the air in the oil cylinder is completely discharged, maintain sufficient space, the workbench should be kept in a horizontal state.

Every theater is a public place with a large number of people,OstrovinkaHigh altitude electric elevator, and safety considerations should be taken into account in stage design. According to relevant national regulations, in order to prevent accidents caused by the crushing of electric elevators or improper control by drivers. Electric elevators should be equipped with the following necessary safety devices to ensure that the car of the electric elevator stops rising or falling in a timely manner.

.Model Example: Hanging Cage Specification: LABSC200/200TD3200x1500 Type I: 2900~3600 Type II: 2900~3600 Type V: 1800~250044003800 Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x0.02 (kN).

The L distance depends on the selected wall mount model.

Setting requirements: The quality of the standard section should meet the requirements of the product manual. Before installing the construction electric elevator, all components should be inspected, and standard sections and other components with severe wear and deformation should be replaced.


Ostrovinka5 meter electric spiral elevatorConcentrated competition in the industry



The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.

Degrees, m/s.

The net height of the landing door opening should not be less than 8m and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

index.Mechanical devices controlled by cage movement should not be used to open or close the landing door.

When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.

The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit,OstrovinkaZoomlion Electric Elevator, and verified by experts.


Ostrovinka5 meter electric spiral elevatorConcentrated competition in the industry



Pipeline rupture valve: When the hydraulic system pipeline ruptures and the car stalls and descends, it can automatically cut off the oil circuit and stop descent

discount.The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

Greater than 0.04s; When the hydraulic buffer is used, the oil level shall be checked, the cage shall not

The list of materials for making landing doors is as follows: Table 1: List of materials for making landing doors. Landing doors should be installed at the entrance of each landing station, and the landing doors should function properly.

Ostrovinka.When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

When the wall bracket cannot meet the requirements of the construction site, it should be designed and calculated separately.

To meet the needs of stage craftsmanship and layout; Product; In the music and dance theater stage arranged in a zigzag pattern, auxiliary lifting platforms are often arranged in front, back, left, and right of the main stage lifting platform. The side and rear auxiliary lifting platforms are used for the smooth opening of the side platform and rear vehicle turntable, while the front auxiliary lifting platform is used to place the rear vehicle turntable near the platform entrance. The leveling lifting platform below the side platform and rear vehicle turntable can be used to level the platform after the side platform or rear vehicle turntable is driven out, so that the entire platform does not have a height difference, ensuring the safety of the cast members.