ParasaswarFixed hydraulic lifting platformThe product must have a high cost

announcer:hp530HP141750488 release time:2024-03-04 12:31:55

Reason: Cleaning method for internal leakage in the oil cylinder: Replace the sealing element of the oil cylinder. The lifting platform does not lower. Reason: The lowering valve is malfunctioning. Cleaning method: When pressing the lowering button, check whether the lowering valve is powered on. If there is no electricity, clean it as much as possible; If there is power, clear the malfunction of the lowering valve itself or replace the lowering valve. The sliding valve should be kept clean and.

After long-term use of the automatic lifting platform equipment, it is inevitable that some malfunctions will occur. In order not to affect work, it is necessary to promptly solve the difficulties in starting the motor and abnormal sounds. Generally due to overload, and a small cross-sectional area of the power supply cable, the starting voltage drop is too large and the price of the cargo elevator is reduced.

Parasaswar.Below, we will analyze for everyone. According to the market survey and understanding conducted by the editor of hydraulic freight elevator manufacturers, many customers choose hydraulic elevators instead of elevators due to the following reasons: narrow transportation location, which cannot meet the requirements of elevators; Unable to excavate the elevator shaft at the working location; Elevators are expensive and difficult to meet their needs.

Ensure that there is a suitable power supply at the installation site, and separate maintenance of the distribution box is required. The distribution box should have a leakage switch, and the hydraulic cargo elevator construction site should be equipped with a fire extinguisher to prevent welding operations from causing fires. When selecting a leakage switch, it should be suitable for the operating power.

.The hydraulic oil used in the system has the same brand, and the oil temperature is between 45~80 ℃. Use a large flow rate to remove impurities from the system as much as possible. The hydraulic system needs to be cleaned repeatedly three times or more, and after each cleaning, the system should be drained while the oil is hot. After cleaning, clean the filter and add new oil after using a new filter element.

Voltage too low: Measure the starter voltage, cargo warehouses it is necessary to replace it immediately. The protection of steel wire ropes should strictly follow the rules of GB5144-85.

Hydraulic cargo elevators are mainly used for the transportation of high-altitude goods such as factory assembly lines,ParasaswarHydraulic lifting table small, parking lots, docks, logistics, etc. This product can achieve multi-point, interactive interlocking between upper and lower floors, achieving safe use and carrying capacity of 30 tons. The above are the fields in which hydraulic cargo elevators are applied and the characteristics of hydraulic cargo elevators that we want to share with everyone.

The hydraulic elevator overflow valve can also generate high noise. When air is mixed in hydraulic oil,ParasaswarSmall hydraulic lifting and leveling, the overflow valve is stuck or severely worn, the spring of the overflow valve is fatigued and deformed, resulting in unstable pressure regulation of the overflow valve, and the relief time of the overflow valve is too short, it is easy to cause the pilot valve performance of the overflow valve to be partially stable, causing air to vibrate inside the pilot valve and generate noise. So we need to regularly clean the overflow valve. When the overflow valve is damaged or severely worn it should be replaced.

Honest management.Users should arrange dedicated personnel to operate hydraulic elevators, formulate usage details and safety precautions for hydraulic elevators based on their own situation, and hang them on the

There is noise inside the hydraulic cylinder. When replacing the hydraulic oil, there was air in the hydraulic cylinder due to an operational error. Under high pressure, it is easy to generate cavitation and high-frequency noise. When the rod is bent or replaced with a new seal, the new seal is too tight which can also produce significant noise. If it is a problem of tight sealing, the noise can be reduced after running in for a period of time. If the rod is bent, it needs to be corrected. In addition, hydraulic pipelines should use hoses as much as possible, even when arranging pipelines, it can reduce vibration and noise, and the pipelines should avoid dead bends as much as possible.

Each brush should be kept clean on its surface, and the brush pressure should be adjusted to ensure that its area is not less than 50%.


ParasaswarFixed hydraulic lifting platformThe product must have a high cost



The elevator itself has a simple structure and is easy to maintain, which has been favored by a large number of enterprises and individual customers. Hydraulic elevator is a multifunctional heavy loading and unloading mechanical equipment. The lifting system of hydraulic elevators is driven by hydraulic pressure, also known as hydraulic powered elevators.

Product line.Regularly check whether each organization is functioning properly and whether there is noise. If problems are found, usually made of high-quality carbon steel with a carbon content of 0.5% -0.8%. They are widely used as transmission components in elevators. Due to its large load-bearing capacity, smooth operation, no noise, suitable for high-speed transmission, high strength, strong overload capacity,ParasaswarScissor fork hydraulic lifting table, and reliable operation, it has become a commonly used rope for hydraulic elevators.

The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects). The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve hydraulic control one-way valve, throttle valve, and explosion-proof electromagnetic directional valve. To ensure a smooth descent of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure, so that the descent speed does not change due to heavy objects. The throttle valve regulates the flow rate and the ascending and descending speed. To ensure safe and reliable braking and prevent accidents, a hydraulic control one-way valve, also known as a hydraulic lock, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure.

Parasaswar.The hydraulic lifting platform often checks the connection status of each part, and if there is any looseness, it should be tightened. The connection bolts of the machine body should be checked for tightness when the elevator body is under pressure (the compression condition can be formed by rotating the arm). All connecting shafts need to have split pins and need to be fully opened.

The guide rail type elevator has a structure of a straight top oil cylinder. The linear operation of the oil cylinder pulls the transmission chain, driving the lifting of the table to complete the operation. The guide rail type elevator is a popular form of cargo elevator in recent years, with the advantages of higher lifting height, stable operation, and simple maintenance compared to the scissor fork type elevator.

A hydraulic elevator is a type of elevator equipment consisting of a walking mechanism, hydraulic mechanism, electric mechanism, and support mechanism. The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge.