MasalaElevating cargo elevator 1-4 floorsMaterial selection

announcer:hp779HP136589660 release time:2024-02-21 10:20:08

The load of this series of products is divided into 0.1 to 0.8 tons, and can also be customized according to user requirements, Italian imported pump station with external protective devices: organ m type, mesh type and iron plate sealed type.

Masala.Manual hydraulic platform classification: Manual hydraulic lifting platform vehicles can be divided into manual hydraulic handling platform vehicles, manual hydraulic stacking platform vehicles, and manual hydraulic shear type platform vehicles.

Hydraulic lifting platforms are widely used in factory maintenance, municipal construction, and decoration of hotels in industrial and mining enterprises, with reliable quality and perfect performance.

.Test the goods elevator every day to see if it can operate normally.

Test the goods elevator every day to see if it can operate normally.

Hydraulic lifting platforms are widely used in factory maintenance municipal construction, and decoration of hotels in industrial and mining enterprises, with reliable quality and perfect performance.


MasalaElevating cargo elevator 1-4 floorsMaterial selection



Secondly, there should be no dirt on the friction surface. If there is any dirt, it should be washed off with gasoline or thinner; The reduction gearbox, gearbox, external meshing gear, and other parts of the equipment, as well as the hydraulic oil, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations, and promptly remove all faults; When installing, disassembling, and adjusting the rotating mechanism of the equipment, it is important to note that the reducer and the gear center line should be parallel, and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables, and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings, distribution boxes, and brushes of the motor are kept clean, and that the travel switch points of each safety device must be safe and reliable.

Chemical derusting is a type of derusting that uses acid to chemically react with the metal parts of the screw elevator to remove the rust products on the rust surface of the push rod. This type of derusting is mainly used for large mechanical screw elevators, and attention should be paid to protecting precision components such as electronic instruments during use to avoid acid corrosion.

The elevator is a kind of elevator equipment composed of a walking mechanism, a hydraulic mechanism, an electric mechanism, and a support mechanism. The hydraulic oil forms a certain pressure by a vane pump,MasalaElevating cargo elevator 1-4 floors, and enters the lower end of the hydraulic cylinder through an oil filter,MasalaA cargo elevator, flameproof electromagnetic directional valve, throttle valve, hydraulic control one-way valve and balance valve. This allows the hydraulic cylinder to move upward and lift heavy objects. The return oil from the upper end of the hydraulic cylinder returns to the tank through the flameproof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. Observe the reading value of the pressure gauge on the pressure gauge.

retailer.Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.

Hydraulic pump station: domestic lifting platform dedicated pump station, Italian imported pump station with external protective devices: organ m type, mesh type, and iron plate sealed type.

To ensure excellent power supply at the installation site, install a separate distribution box. When using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.


MasalaElevating cargo elevator 1-4 floorsMaterial selection



The motor winding is short-circuited. When a short circuit fault occurs in the motor winding, the short circuit current is much larger than the normal working current, which increases the copper loss of the winding, causing the winding to overheat or even burn out.

recommend.In addition, it is strictly prohibited to use a hammer during installation to prevent excessive axial or radial force from damaging the bearings or gears. Be sure to tighten the mounting bolts before tightening the tension bolts. Before installation, clean the anti rust oil on the motor input shaft, positioning boss, and elevator connection parts with gasoline or zinc sodium water. Its purpose is to ensure the tightness of the connection and the flexibility of operation, the staff should carefully check the hydraulic and electrical systems to ensure there is no leakage or bare leakage before using it.

Different. (Specific bearing capacity and lifting height can be designed and customized according to user requirements)

Masala.Before installing the elevator, confirm whether the motor and the elevator are intact,MasalaElevating cargo elevator factory building, and strictly check whether the dimensions of each part connecting the motor and the elevator match. Here are the dimensions and fit tolerances of the positioning boss input shaft, and elevator groove of the motor.

Connect the motor to the elevator naturally. During connection, it must be ensured that the concentricity of the elevator output shaft and the motor input shaft is consistent, and that the outer flanges of the two are parallel. Inconsistent centering can cause the motor shaft to break or the elevator gear to wear.

Prepare the foundation according to the foundation plan, pay attention to alignment, and alignment, and ensure the level of the foundation and various usage requirements.