XigenMobile electric elevatorInspection and replacement operation

announcer:hp935HP175192871 release time:2024-02-21 10:20:09

In addition to ground protective fences, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings, a half height middle crossbar, and a toe board at least 150mm above the ground.

The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.

Xigen.8m; When the lifting speed is greater than 0.8m/s, after the upper limit switch is triggered by the hanging cage, the upper small safety distance L should meet the following requirements: L=8+0.1V2, where L is the upper safety distance; V: Increase speed

The landing door should be in a normally closed state. Without the permission of the construction electric elevator driver,XigenElectric one ton elevator, the landing door shall not be opened.

.Setting requirements: The landing door should be standardized and tooled.

Especially suitable for steel structured factories, suitable for both indoor and outdoor installation.

The use of a lifting platform as a tool for storing performance blankets, etc. In some theaters, there is a soft scenery storage lifting platform located at an appropriate location on the stage for the storage of blankets, soft scenery, etc.


XigenMobile electric elevatorInspection and replacement operation



Setting requirements: Each landing entrance should be equipped with a landing door, which should cover the opening with its full width, and should not open towards the lifting passage.

Mobile electric elevators are divided into: four wheel mobile lifting platform, two wheel traction lifting platform car modified lifting platform, manual lifting platform, manual lifting platform, all equipped with imported high-quality pump stations, which can also be selected according to customer requirements to meet customer ideal requirements.

The landing door should meet the requirements of the specifications and achieve standardization.

The quality of the standard section should comply with the product manual and specification requirements.


XigenMobile electric elevatorInspection and replacement operation



Pipeline rupture valve: When the hydraulic system pipeline ruptures and the car stalls and descends it can automatically cut off the oil circuit and stop descent

consumption.As a material loading and unloading equipment recognized by customers in the lifting platform, the guide rail hydraulic lifting platform is superior in terms of product, civil engineering, and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load, can achieve multiple points, and can be controlled up and down floors to achieve safe use.

The pressure joint between the pipe joint and the rubber hose fails prematurely, causing oil leakage or pipe explosion. The oil temperature rises due to frequent action of the overflow valve.

Monthly maintenance and inspection of hydraulic lifting platform rollers intermediate shafts and bearings, oil cylinder pin shafts and bearings, boom hinge shafts and bearings for wear. Add some oil to each part to extend the service life of the lifting platform bearings. The quality and level of hydraulic oil. The lifting platform should be raised throughout the entire process, and at this position, the hydraulic ground should be 40-50 millimeters higher than the bottom of the box. If the hydraulic oil becomes dark, or has foreign objects such as gravel, it should be replaced in a timely manner (32 # hydraulic oil). Annual maintenance and inspection of all hydraulic pipelines and joints of the lifting platform. The pipeline must not be damaged, and the joints must not be loose. All joints must be tightened. Remove and disassemble the lowering valve of the lifting platform, blow out the plunger with compressed air,XigenElectric elevator 6 meters, then install it and reinstall it. Drain and discard the hydraulic oil, tighten the joint, remove the oil filter, clean it with compressed air, and then return it to the oil tank and connect the pipeline.

Xigen.Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.

The oil cylinder and sealing components are made of imported components to solve the problem of unstable oil pressure and oil leakage of components for customers.

Advantages of electric elevator rotary valve: Simplify the installation of electric elevator pipelines; The operation is more convenient, and the valve can be opened and closed at any time; The installation of a rotary valve reduces the friction of the sealing components; Compact structure, small size, and space saving; Increased the service life of electric elevator pipelines and solved the problem of easy oil leakage.