southern suburbsElectric brick elevator on construction siteStrengths and weaknesses in product use

announcer:hp935HP175192871 release time:2024-02-07 12:24:24

Secondly, for the replacement of hydraulic oil on the lifting platform, it is recommended to replace it every three months. If the frequency of use is not high, it can be replaced once a year. The hydraulic oil must be clean, and after changing the hydraulic oil, it must be automatically lifted and lowered 2 to 3 times to ensure that the air in the oil cylinder is completely discharged, maintain sufficient space, and ensure that the lifting platform can be lifted to the rated lifting height.

During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.

southern suburbs.The safety overtravel of limit switches and upper limit switches should comply with regulatory requirements.

When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

.The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

Electric elevators used in various places.

To meet the needs of choreographers and choreographers in different plays, different heights of the lifting platform can be used to change the shape of the stage according to the requirements of the choreographers and choreographers,southern suburbsThree meter electric elevator, in order to adapt to the requirements of the plot for the scenery or venue, a better highlighting effect can be achieved in various performances. According to the needs of the plot,southern suburbsDedicated electric elevator, special atmosphere and effects can be created. Even simple stage machinery often participates in performance activities, creating unexpected atmosphere and effects according to the needs of the plot. For example, and the valve can be opened and closed at any time; The installation of a rotary valve reduces the friction of the sealing components; Compact structure using the valves on the lifting platform and the sudden disappearance and appearance of actors on the lifting platform.


southern suburbsElectric brick elevator on construction siteStrengths and weaknesses in product use



Advantages of electric elevator rotary valve: Simplify the installation of electric elevator pipelines; The operation is more convenient, small size, such as factory maintenance, airport maintenance, street light maintenance and so on; How to use electric elevators correctly to extend the service life of the equipment and be flexible

Speed limiter. To prevent the driving speed from exceeding the normal speed. A speedometer should be installed (not required for floors below or including the second floor),southern suburbsStage electric elevator, which is an individual mechanism that is integrated with a safety clamp; The entrance and exit of the passenger compartment should be equipped with safety doors. Public places, family dormitories, and

Latest consultation.Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops

The full height landing door should meet the following requirements: the net height of the landing door opening should not be less than 0m. In special circumstances, when the net height of the building entrance is less than 0m, it is allowed to lower the height of the lower door opening, but in any case, the net height of the lower door opening is not less than 8m. (Article 1 of GB26557-2011)

Setting requirements: The verticality deviation of the installation of the guide rail frame of the construction electric elevator should comply with the requirements of the user manual and specifications, as specified in the above table.


southern suburbsElectric brick elevator on construction siteStrengths and weaknesses in product use



When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test, it worked normally.

discount.During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

Stop the suspension cage.

Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position

southern suburbs.Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

The use of standard section connecting bolts should comply with the user manual and specification requirements.

The landing door should meet the requirements of the specifications and achieve standardization.