NasChain lifting cargo elevatorPursue a diversified industry model

announcer:hp779HP136589660 release time:2024-01-18 15:55:45

Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that,NasGuide rail lifting cargo elevator,NasFixed hydraulic lifting cargo elevator, remove the motor shaft key.

To ensure excellent power supply at the installation site, install a separate distribution box. When using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

Nas.The manual hydraulic scissor type platform car has the following characteristics: suitable for long-distance transportation; Treadable feet and protective devices; Lightweight and easy to lift; Unique caster design ensures safety; The engineering handle design makes the operator comfortable to operate.

This fixed lifting device can also be used inside a warehouse, such as lifting a certain layer of the warehouse to transport goods or personnel to a designated warehouse location.

.It is strictly prohibited for personnel to climb up and down the floors by using the goods elevator privately.

The hydraulic lifting platform mainly uses hydraulic oil pressure transmission to achieve the lifting function. Its shear fork mechanical structure provides stability for the lift. The wide working platform and high bearing capacity make the high-altitude operation range wide and suitable for multiple people to work simultaneously. It makes aerial work efficient and guaranteed.

The water cooling of hydraulic stations is generally tubular water cooling, and the type selection is based on the heat load to calculate the heat exchange area, and the heat exchange capacity is calculated based on the heat load. Then, the type selection calculation is performed when the flow can be satisfied. Therefore, the two types of cooling are different, and there are significant differences. Long-term lifting and lowering of cargo elevator factory


NasChain lifting cargo elevatorPursue a diversified industry model



Systems: explosion-proof electronic control system, remote control system, and random adjustment can easily cause internal pressure to increase or decrease, which in severe cases can shorten the service life of the motor.

Connect the motor to the elevator naturally. During connection, it must be ensured that the concentricity of the elevator output shaft and the motor input shaft is consistent, and that the outer flanges of the two are parallel. Inconsistent centering can cause the motor shaft to break or the elevator gear to wear.

Respect for customers.Corrosion prevention measures for the body of aerial work vehicles Attention to small scratches The paint surface of aerial work vehicles often corrodes. In addition to common collisions scratches, and small rocks on the drive tire, there can also be a paint peeling point that can cause a small rust over time. Because most of these scars are small and easy to ignore. Therefore, regularly inspect the engine compartment lid and surrounding areas, and once found, go to a professional beauty shop for processing in a timely manner.

'Using the elevator is not about maintaining and overhauling the equipment after it has failed. It is important to maintain the equipment in accordance with the correct maintenance and overhaul. First, do the preparatory work to eliminate all possible fault problems and accidents. I hope that today's summary of knowledge points by the editor can help everyone.'.

Motor connection error. When the triangular connection motor is mistakenly connected into a star shape, the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current, leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch, the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat,NasGuide rail chain elevator, the windings will be burned.


NasChain lifting cargo elevatorPursue a diversified industry model



The purpose of hydraulic lifting platform Users can choose the power mode and configuration according to their own scope of use: power systems include: DC power supply, single-phase or three-phase power supply diesel engine.

Job description.In addition to having a fixed mode, there are also types of mobile elevators. As the name implies, it is a combination of lifting equipment and on-board systems. This type of lifting equipment is very flexible to move, and of course, it is better to use it. For example there are such lifting equipment in airports, and stations or stadiums may also be equipped with such equipment, as it can be moved by itself, The scope of work is not limited to a certain place, but can be used wherever lifting operations are required. For example, when installing outdoor advertisements, some advertisements are relatively high in height. At this time, currently, hydraulic lifting platforms are more widely used.

After careful inspection, it was found that there were two main causes: loss of hydraulic pressure, and leakage of hydraulic valves or seals.

The motor winding is short-circuited. When a short circuit fault occurs in the motor winding, the short circuit current is much larger than the normal working current, which increases the copper loss of the winding, causing the winding to overheat or even burn out.

Nas.Prepare the foundation according to the foundation plan, pay attention to alignment, leveling, and alignment, and ensure the level of the foundation and various usage requirements.

Connect the motor to the elevator naturally. During connection, it must be ensured that the concentricity of the elevator output shaft and the motor input shaft is consistent, and that the outer flanges of the two are parallel. Inconsistent centering can cause the motor shaft to break or the elevator gear to wear.

This fixed lifting device can also be used inside a warehouse such as lifting a certain layer of the warehouse to transport goods or personnel to a designated warehouse location.