CarlosaElectric mobile elevator,

The counterweight guide rail should meet the specification requirements.

Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

Carlosa.Is there a relevant rule requirement for the cleanliness of hydraulic stations?

Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

.Spiral electric lifting mechanism: With all the functions of a regular lifting platform, the main feature is that the equipment occupies a small foundation pit and has a large stroke. The equipment has a height of only 200-500mm and a travel distance of up to 14m. It is particularly suitable for buildings with stages built on two or more floors due to space constraints.

During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.


CarlosaSelf propelled electric elevatorHuge infrastructure investment demand



Installation and dismantling personnel and drivers should hold certificates to work.

The suspension cage movement can only be resumed after operator operation.

Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

Installation materials.When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, should comply with the provisions of Table 4 of GB 23821-2009.

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

Horizontal lead screw mechanical electricity


CarlosaSelf propelled electric elevatorHuge infrastructure investment demand



Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

Range.Human improper operation is the main factor causing malfunctions in scissor type electric elevators. When stacking goods, electric elevators should stack the goods neatly,CarlosaElectric bed elevator, which is better than stacking them in the center of the cargo stacking area of the cargo elevator to avoid imbalance between the two ends of the stacking area. Eventually, it may cause the electric elevator to lose balance. After the goods are stacked completely,CarlosaScissor fork electric lifting table, ropes should be used to lock the goods, so that they are not afraid of the goods during the lifting process; Careless; Scattered down

The isolation and buffering rubber in various parts of the aluminum alloy electric elevator drive device are intact and tightly fitted.

Construction electric elevators outside the lightning protection range

Carlosa.The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

The list of materials for making landing doors is as follows: Table 1: List of materials for making landing doors. Landing doors should be installed at the entrance of each landing station, and the landing doors should function properly.

When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test, it worked normally.