NIM.As we all know now, elevators and lifting platforms have been widely used in recent years to solve the problems we encounter in daily life. Because working at heights is a high-risk profession that requires the assistance of auxiliary tools to complete certain tasks, the use of elevators is undoubtedly emerging in the domestic machinery market and has been vigorously developed.

Purpose The hydraulic lift is widely used in various industrial enterprises and production lines such as automobile, container, wood processing, chemical filling, etc., to meet the lifting requirements of different operation heights, and can be equipped with various table forms (such as ball, roller, turntable, steering, tipping, and with various ways (separate, linkage, explosion-proof), it has the characteristics of stable and accurate lifting, frequent starting, and large load capacity, Effectively solve various lifting and lowering operation difficulties in industrial enterprises making production operations free. Professional elevator factory has advanced technology, strict testing, more affordable prices, and more preferential treatment. Welcome to consult

.What is the new price of fixed elevators? Fixed elevators are currently very popular in the market. Due to different manufacturers, different materials, different load ratings, the prices also vary. Currently, the prices of fixed elevators produced in the domestic market are: rated load 1-5 tons, lifting height 7 meters, table size 2500 mm * 2000 mm, and the price is around 27000-45000 yuan; The rated load is 1-3 tons, the lifting height is 0 meters, the table size is 2300 mm * 2000 mm, and the price is around yuan. Rated load and lifting height of each fixed elevator,

Motor connection error. When the triangular connection motor is mistakenly connected into a star shape the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current, leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch, the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat, and in severe cases, single-phase or three-phase power supply, diesel engine.


NIM1 meter fixed lifting cargo elevatorNo new stories, price fluctuations weaken



The elevator is a kind of elevator equipment composed of a walking mechanism, a hydraulic mechanism, an electric mechanism, and a support mechanism. The hydraulic oil forms a certain pressure by a vane pump,NIMFive ton cargo elevator, and enters the lower end of the hydraulic cylinder through an oil filter flameproof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve. This allows the hydraulic cylinder to move upward and lift heavy objects. The return oil from the upper end of the hydraulic cylinder returns to the tank through the flameproof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. Observe the reading value of the pressure gauge on the pressure gauge.

Replace with new oil and do not intermittently use the old oil, otherwise the moving parts in the system will accelerate wear.

What is the new price for fixed elevators? Professional improvement of the quality assurance of the elevator factory. Preferential activities are ongoing, welcome new and old customers to consult

query.Connect the motor to the elevator naturally. During connection, it must be ensured that the concentricity of the elevator output shaft and the motor input shaft is consistent, and that the outer flanges of the two are parallel. Inconsistent centering can cause the motor shaft to break or the elevator gear to wear.

After the goods are transported, they are often exposed to rain and sunlight so special attention should be paid to regular maintenance and inspection to avoid accidents.


NIM1 meter fixed lifting cargo elevatorNo new stories, price fluctuations weaken



Precautions for elevator installation: Keep the access road of external construction elevators smooth and have sufficient space for parking equipment. When using a steam crane for auxiliary installation, full consideration should be given to whether the on-site environment meets the operating conditions of the steam crane.

discount.Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.

Drain and discard the hydraulic oil from the hydraulic lifting cargo elevator. For the outdoor guide rail elevator, tighten the joint and remove the oil filter. After cleaning, clean it with compressed air, and then return it to the oil tank and connect the pipeline.

Is the water cooling and air cooling of the hydraulic station the same?

NIM.Frequently check for water accumulation and humidity. It is inevitable for aerial vehicles to drive in rainy and snowy weather, or muddy roads. The bottom and some gaps and indoor floors are prone to sludge accumulation. If the owner does not clean them in a timely manner, this can cause moisture to hide. Therefore, activities in the outer edges of wheel hubs doors, bottom corners of tree trunks, key holes, and wiper brackets, as well as other areas, should be regularly inspected, and the drainage holes in the doors and various parts should be kept unblocked to ensure that the car seat covers, such as humidity, carpets, and floors, prevent rust from forming parts.

Nowadays, small and medium-sized enterprises are products with the idea of good quality and preferential prices.

Motor connection error. When the triangular connection motor is mistakenly connected into a star shape, the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current,NIMGuide rail lifting cargo elevator lifting, leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch, the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat, and in severe cases, the windings will be burned.