ERDOil pressure track lifting cargo elevatorContraindications when using the product

announcer:hp779HP136589660 release time:2023-12-22 11:43:55

Corrosion prevention measures for the body of aerial work vehicles Attention to small scratches The paint surface of aerial work vehicles often corrodes. In addition to common collisions, scratches, regularly inspect the engine compartment lid and surrounding areas, and once found, go to a professional beauty shop for processing in a timely manner.

Large logistics warehousing equipment service company with guaranteed prices and guaranteed services, directly operated by the manufacturer. Because fixed elevators are mechanical equipment, the quality and performance of the product are good. Do not accept products from some manufacturers that do not meet the quality standards, in order to avoid some safety hazards in use.

ERD.The one-way valve is damaged. The one-way valve is designed to prevent oil return. If there is a problem, there will be some backflow, so it can be replaced at this time.

Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes, with a scissors type mechanical mechanism, easy to maintain, strong stability, and high bearing capacity. The lifting height is about 10 meters,ERD1 ton small lifting cargo elevator,ERD2 ton cargo elevator, and the load capacity is about 10 tons.

.Different. (Specific bearing capacity and lifting height can be designed and customized according to user requirements)

The load of this series of products is divided into 0.1 to 0.8 tons, and can also be customized according to user requirements, with a load of up to 10 tons.

Walking: assisted self-propelled, two wheel traction, self driving, and car modification.


ERDOil pressure track lifting cargo elevatorContraindications when using the product



Motor connection error. When the triangular connection motor is mistakenly connected into a star shape the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current, leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat and in severe cases, the windings will be burned.

The guide mechanism of the guide mechanism of the guide rail elevator manufacturer is mainly composed of guide plastic pipes,ERDElevating cargo elevators from first to second floors, guide brackets, compression springs, safety plugs, guide housings, and guide shafts. As a semi sectional view of the guide mechanism, a narrow gap is formed between the two guide plastic pipes, and the lifting cloth belt extends out of the box from this narrow gap to prevent the cloth belt from being tangled and serve as a guide. The safety plug is supported by a guide bracket and a compression spring. In order to prevent the compression spring from losing stability after being stressed, a small guide rod is designed on the safety plug, and the gap between the small guide rod and the spring is designed according to the table. The crane arm shaft is welded and installed with a crane arm hook at both ends. The material is selected and subjected to conditioning treatment. It forms three suspension points with the hook at the lower shell of the box. The soft support sling will be lifted by the person being lifted. The load bearing capacity of the crane arm is designed to ensure that the person being lifted can be in a comfortable state when riding. The distance between the two crane arm hooks is listed in the table as a design reference, and the balance bar is used to maintain the balance of the lifting device, reducing the overall weight of the boom.

Motor connection error. When the triangular connection motor is mistakenly connected into a star shape, the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current, leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch, the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat, the windings will be burned.

Welcome calls .This fixed lifting device can also be used inside a warehouse, such as lifting a certain layer of the warehouse to transport goods or personnel to a designated warehouse location.

Before connecting the motor to the elevator, the elevator manufacturer should first make the motor shaft keyway perpendicular to the tightening bolt. To ensure uniform stress, first screw on the mounting bolts at any diagonal position, but do not tighten them. Then screw on the other two mounting bolts at diagonal positions, and then tighten the four mounting bolts one by one. After that, tighten the tightening bolts. All tightening bolts shall be fixed with a torque wrench according to the indicated fixed torque data, and the use of elevators and lifting platforms shall be checked

Scissor type fixed lifting platform is a transportation and loading equipment that transports goods from one height to another. After operation, the platform is level with the ground, without occupying ground space and affecting passage passage.


ERDOil pressure track lifting cargo elevatorContraindications when using the product



The load of this series of products is divided into 0.1 to 0.8 tons, and can also be customized according to user requirements, with a load of up to 10 tons.

Latest quotation.Prepare the foundation according to the foundation plan, pay attention to alignment, leveling, and alignment, and ensure the level of the foundation and various usage requirements.

As we all know now, elevators and lifting platforms have been widely used in recent years to solve the problems we encounter in daily life. Because working at heights is a high-risk profession that requires the assistance of auxiliary tools to complete certain tasks, the use of elevators is undoubtedly emerging in the domestic machinery market and has been vigorously developed.

Test the goods elevator every day to see if it can operate normally.

ERD.Hydraulic pump station: domestic lifting platform dedicated pump station, Italian imported pump station with external protective devices: organ m type, municipal construction and iron plate sealed type.

Hydraulic lifting platforms are widely used in factory maintenance, and decoration of hotels in industrial and mining enterprises, with reliable quality and perfect performance.

The water cooling of hydraulic stations is generally tubular water cooling, and the type selection is based on the heat load to calculate the heat exchange area, while the air-cooled elevator is conducted using an air cooler, and the heat exchange capacity is calculated based on the heat load. Then, the type selection calculation is performed when the flow can be satisfied. Therefore, the two types of cooling are different, and there are significant differences. Long-term lifting and lowering of cargo elevator factory