PhiladelphiaTatami electric elevatorWhat is it for?

announcer:hp935HP175192871 release time:2023-12-21 11:02:36

The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.

Work is essential, and the main protective accessories include safety belts, guardrails, platforms and stairs,Philadelphia1 ton electric elevator, etc.

Philadelphia.The body in the lateral adjustment device of the driving plate should ensure a compressed state, so that the gear has a certain radial constraint and ensure that the gear and rack always mesh well throughout the entire operation.

Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

.Speed limit wire rope switch. When the speed limit wire rope trips or breaks. Make the electric elevator unable to start.

The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator, with a size of 8 meters by 2 meters.

Principle of electric elevator rotary valve: When the electric elevator rises, the rotary valve will automatically open. To close the plug valve, it is necessary to first turn the handle to turn the plug to a 90 degree position until it is closed, and then turn the transmission handwheel to lower the plug and achieve sealing.


PhiladelphiaTatami electric elevatorWhat is it for?



The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.

The downward movement of the hydraulic cylinder (i.e. heavy object lowering). The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder passes through the balance valve, hydraulic control one-way valve, for the replacement of hydraulic oil on the lifting platform and explosion-proof electric valve

Secondly, it is recommended to replace it every three months. If the frequency of use is not high, it can be replaced once a year. The hydraulic oil must be clean, and after changing the hydraulic oil, it must be automatically lifted and lowered 2 to 3 times to ensure that the air in the oil cylinder is completely discharged, maintain sufficient space, and ensure that the lifting platform can be lifted to the rated lifting height.

Word of mouth recommendation.Advantages of electric elevator rotary valve: Simplify the installation of electric elevator pipelines; The operation is more convenient, and the valve can be opened and closed at any time; The installation of a rotary valve reduces the friction of the sealing components; Compact structure, small size, a hydraulic control one-way valve, also known as a hydraulic lock, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB1&flash; The rotation of the SB6 motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease, and; Program adjustment time delay to avoid frequent movement of electric elevators that may affect their service life.

High lifting height, using side mounted oil cylinders, stable operation, noise free, easy maintenance, and longer service life.


PhiladelphiaTatami electric elevatorWhat is it for?



According to the needs of different performance genres, the form of the stage can be changed. For example, using an orchestra pit lift can combine a framed stage with a large lip or even an extended stage. In an experimental theater, using a lift can make the theater have various forms such as an end stage, an extended stage, an island stage,PhiladelphiaElectric elevator mobile type, an intermediate stage, a T-shaped stage, or a hall.

Promotion.Acceptance: Concrete strength grade C30, strength testing report.

Is the water cooling and air cooling of the hydraulic station the same?

When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.

Philadelphia.Construction electric elevators outside the lightning protection range

Emergency manual valve: In case of power failure, it can cause the car to descend to the nearest floor position and open the door

Civil engineering advantages: The pit depth of the guide rail type lifting platform is generally around 150-300mm, and the top layer is not affected. It can be customized according to the location and environment.