electric elevators should stack the goods neatly, which is better than stacking them in the center of the cargo stacking area of the cargo elevator to avoid imbalance between the two ends of the stacking area. Eventually, during the operation of the electric elevator, it may cause the electric elevator to lose balance. After the goods are stacked completely, ropes should be used to lock the goods, so that they are not afraid of the goods during the lifting process; Careless; Scattered down

BaileAtha I.Equal effect.

The foundation base or embedded parts should be fully embedded in the concrete foundation plate.

.When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

From the above comparison, it can be seen that hydraulic electric lifting mechanisms have stable lifting low noise, long service life, large load bearing capacity, and are relatively simple,BaileAtha IBlue cover electric elevator, making them suitable for use in stage equipment.

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.


BaileAtha ISelf propelled electric elevatorConcentrated competition in the industry



Vertical lead screw electric lifting mechanism: Adopting a lead screw transmission method, it can achieve the lifting of a double-layer tabletop. Multiple lifting platforms can be formed as needed, and different steps can be formed within the travel range to meet the needs of meetings and performances; Pavilion Terrace, Tower, Pavilion; Ideal props.

Mobile electric elevators are divided into: four wheel mobile lifting platform, two wheel traction lifting platform, car modified lifting platform, manual lifting platform, manual lifting platform, and AC/DC dual purpose lifting platform

The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

High quality and low price.Speed limit wire rope switch. When the speed limit wire rope trips or breaks. Make the electric elevator unable to start.

The use of standard section connecting bolts should comply with the user manual and specification requirements.

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.


BaileAtha ISelf propelled electric elevatorConcentrated competition in the industry



The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

Potential development.The use of a lifting platform as a tool for storing performance blankets, soft scenery, etc. In some theaters,BaileAtha I6m electric elevator,BaileAtha I2 ton electric elevator, there is a soft scenery storage lifting platform located at an appropriate location on the stage for the storage of blankets, soft scenery, etc.

8m; When the lifting speed is greater than 0.8m/s, after the upper limit switch is triggered by the hanging cage, the upper small safety distance L should meet the following requirements: L=8+0.1V2, where L is the upper safety distance; V: Increase speed

Setting requirements: Each landing entrance should be equipped with a landing door, which should cover the opening with its full width, and the neutral wire should not be arbitrarily held as a safety grounding wire. Its grounding resistance should not exceed 4 ohms; The power supply of the electric elevator can be cut off.

Use floor doors and cage door devices on construction sites where conditions permit.