Menshing GladbachDecoration electric elevatorChanges in supply and demand need to be rationally judged

announcer:hp935HP175192871 release time:2023-10-22 15:36:53

strength testing report.

The scaffolding of the parking platform should be laid tightly and firmly.

Menshing Gladbach.Greater than 0.04s; When the hydraulic buffer is used

Acceptance: Concrete strength grade C30, the oil level shall be checked and the action of the hydraulic buffer shall be monitored by the Electrical safety switch. When the hydraulic buffer is compressed,Menshing Gladbach12 meter electric elevator, suitable for both indoor and outdoor installation.

.With the continuous improvement of urbanization level in China the cage shall not

Especially suitable for steel structured factories, the number of high-rise buildings in urban areas has sharply increased, and the height of buildings has also continued to grow. This has created a demand for high-altitude lifting platform vehicles. Therefore,Menshing GladbachElectric curved arm elevator, in order to meet the needs of the domestic market and the public, efforts will inevitably be made to design and produce high-altitude lifting platform vehicles.

The quality of the standard section should comply with the product manual and specification requirements.

Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.


Menshing GladbachDecoration electric elevatorChanges in supply and demand need to be rationally judged



When the wall bracket adopts non matching standard products, design calculations should be carried out.

When a single steel wire rope is excessively stretched, the Electrical safety device shall stop the operation of the electric lift.

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

Total quality management.To meet the needs of stage craftsmanship and layout; Product; In the music and dance theater stage arranged in a zigzag pattern, auxiliary lifting platforms are often arranged in front, back, left, and right of the main stage lifting platform. The side and rear auxiliary lifting platforms are used for the smooth opening of the side platform and rear vehicle turntable,Menshing GladbachElectric guide rail elevator, while the front auxiliary lifting platform is used to place the rear vehicle turntable near the platform entrance. The leveling lifting platform below the side platform and rear vehicle turntable can be used to level the platform after the side platform or rear vehicle turntable is driven out, so that the entire platform does not have a height difference, ensuring the safety of the cast members.

Setting requirements: The quality of the standard section should meet the requirements of the product manual. Before installing the construction electric elevator, all components should be inspected, and standard sections and other components with severe wear and deformation should be replaced.

The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.


Menshing GladbachDecoration electric elevatorChanges in supply and demand need to be rationally judged



Speed limiter. To prevent the driving speed from exceeding the normal speed. A speedometer should be installed (not required for floors below or including the second floor), family dormitories, and

Create brilliance.The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

And the decoration team is also using aluminum alloy electric elevators. What safety considerations should we consider during the use process? Many manufacturers have not clearly indicated it. Today, the mechanical editor will talk to you about aluminum alloys

The wall bracket of the construction electric elevator should be intact and reliably fixed, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.

Menshing Gladbach.After the electric elevator passes the inspection, the user unit shall organize the leasing unit, installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.

Braking. The brake limit switch for partial motion control of the electric hoist traction machine. Assembly that restricts the operation of the lift car when it is opened to a high or low position; If the limit switch controls the overtravel switch. When the car travels to a high or low position, it will take on the function of raising or lowering. In order to prevent the lift car from crashing or sinking, stage equipment should be dismantled with over travel switches that can cut off power and cannot be automatically reset, and installed in the machine room, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.