TarantoElectric guide rail elevatorVigorously advocate the maintenance of order

announcer:hp935HP175192871 release time:2023-09-16 14:25:12

When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above, effective protective measures should be taken.

Many theaters use a lifting platform as a vertical transportation tool for goods. The rear of the main stage or the end of the side stage in many theaters are equipped with a set container transportation lifting platform, etc.

Taranto.Check whether the sealing of components such as the oil cylinder, oil pipe, and motor of the aluminum alloy electric elevator is good and whether there is any air leakage.

Vertical lead screw electric lifting mechanism: Adopting a lead screw transmission method it can achieve the lifting of a double-layer tabletop. Multiple lifting platforms can be formed as needed, and different steps can be formed within the travel range to meet the needs of meetings and performances; Pavilion Terrace, Tower, Pavilion; Ideal props.

.From the perspective of the safety performance of the machinery itself, those that have undergone national safety certification will not have significant safety issues. The main problem is that after using the electric elevator for a period of time, mechanical components may fall off or be damaged due to various factors. This problem depends on regular inspection and maintenance of the machinery

Setting requirements: The anti loosening and anti loosening parts between the connecting parts should comply with the provisions of the user manual and should not be replaced by other objects. For connecting bolts with pre tightening requirements, a torque wrench or special tool should be used to accurately tighten the bolts to the specified torque value according to the specified tightening sequence. When installing standard section connecting bolts, it is advisable to place the screw at the bottom and the nut at the top.

Low power consumption: When the hydraulic guide rail lifting platform descends,TarantoElectric elevator factory, it is driven by the pressure generated by its own weight, greatly saving energy and reducing consumption.


TarantoElectric guide rail elevatorVigorously advocate the maintenance of order



The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance,TarantoElectric basket elevator, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.

Normal operation starts. Click on this free download of construction technical information. Safety limit devices should be installed on electric elevators for construction, it can be seen that hydraulic electric lifting mechanisms have stable lifting, low noise, long service life, large load bearing capacity, and are relatively simple, making them suitable for use in stage equipment.

Fair price.Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness, strength, stability, and the production should meet the design requirements.

The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements,TarantoElectric hydraulic elevator 15 meters, otherwise protective measures shall be taken.


TarantoElectric guide rail elevatorVigorously advocate the maintenance of order



Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

Trustworthy.The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.

Construction electric elevators must be equipped with lifting cages and reusable buffers, and comply with regulatory requirements.

The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.

Taranto.The use of standard section connecting bolts should comply with the user manual and specification requirements.

The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.

Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops