JacksonvilleElectric small elevatorLaw enforcement inspection

announcer:hp935HP175192871 release time:2023-08-07 12:40:57

with a size of 8 meters by 2 meters.

Operating cost advantage and low failure rate: Due to the use of advanced hydraulic systems and good methods, the operating failure rate can be reduced to a low level.

Jacksonville.The impact load can cause early wear, fracture, and fragmentation of mechanical structural components, as well as generate impact pressure in the hydraulic system, which in turn can damage hydraulic components, oil seals, the protective measures taken should comply with the specification requirements.

.The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

Every theater is a public place with a large number of people, and safety considerations should be taken into account in stage design. According to relevant national regulations in order to prevent accidents caused by the crushing of electric elevators or improper control by drivers. Electric elevators should be equipped with the following necessary safety devices to ensure that the car of the electric elevator stops rising or falling in a timely manner.

When the landing door is closed, the full width of the lifting passage opening should be covered.


JacksonvilleElectric small elevatorLaw enforcement inspection



Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors, wiring, and oil cylinder once a week to avoid dust and debris affecting normal operation.

When using lifting equipment, the workbench should be kept in a horizontal state.

When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

where.During normal operation the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Setting requirements: The landing door should be standardized and tooled.


JacksonvilleElectric small elevatorLaw enforcement inspection



To meet the needs of choreographers and choreographers in different plays, different heights of the lifting platform can be used to change the shape of the stage according to the requirements of the choreographers and choreographers, in order to adapt to the requirements of the plot for the scenery or venue,JacksonvilleIndoor small electric elevator, and save manpower and material resources for setting up. By using the tilting device of the lifting platform to form a tilted platform,JacksonvilleTwo phase electric elevator, a better highlighting effect can be achieved in various performances. According to the needs of the plot, special atmosphere and effects can be created. Even simple stage machinery often participates in performance activities, creating unexpected atmosphere and effects according to the needs of the plot. For example, using the low-speed descent of the lifting platform to represent a sunken ship in the sea, using the valves on the lifting platform and the sudden disappearance and appearance of actors on the lifting platform.

production.Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.

Non automatic reset upper and lower limit switches should be installed at both the upper and lower ends of the stroke which should be able to cut off the power supply before the suspension cage and other mechanical stop devices (such as buffers),JacksonvillePlatform electric elevator,

Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

Jacksonville.When the landing door is closed, the full width of the lifting passage opening should be covered.

To ensure safe and reliable braking of the lifting platform and prevent accidents, a hydraulic control one-way valve, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB1&flash; The rotation of the SB6 motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease, and; Program adjustment time delay to avoid frequent movement of electric elevators that may affect their service life.

To ensure safe and reliable braking of the lifting platform and prevent accidents, a hydraulic control one-way valve, also known as a hydraulic lock, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB1&flash; The rotation of the SB6 motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease, and; Program adjustment time delay to avoid frequent movement of electric elevators that may affect their service life.