SalfeldenDry type transformer ReportHow to perform a stress test

announcer:hp122HP117294921 release time:2024-02-18 09:37:36

Noise pollution control and prevention measures of dry-type transformer

& ldquo; of wiring transformer; Enter & rdquo; And & ldquo; Output & rdquo; Use a megger to test the grounding resistance between the terminal and the ground wire. When accurately measured by 1000V megger, the resistance value exceeds 2m ohm bus.

Salfelden.How to maintain dry-type transformer?

Analysis of common faults of oil immersed transformer:

.Noise solution of dry-type transformer

The manufacturing process of dry-type transformer is very process, and must be technically as a certain pillar. Only in that way, the performance of dry-type transformer will be more stable. What are the common manufacturing processes and steps of dry-type transformer?

The insulating layer shaft and the connecting articles between the bell jar and the core shall be removed. If it is a hanging bell inspection, the oil shall be pumped into the bottom of the bell jar before the bell jar can be removed.


SalfeldenDry type transformer ReportHow to perform a stress test



Wiring mode of dry-type transformer:

Dry type transformer is a common electrical equipment which can be used to convert the alternating voltage of one standard value into another standard value of the same frequency. The step-up dry-type transformer is used to convert the low-grade alternating voltage into another high-grade alternating voltage of the same frequency. It is widely used in high-frequency industries, and a guardrail of no less than 7m shall be installed around it, and a warning sign shall be hung at a prominent position.

The representative mode of connection group of dry-type transformer is: English capital letters indicate the wiring on the primary side (or primary side), and English letters indicate the wiring on the secondary side (or secondary side). Y (or y) is star wiring, and D (or D) is triangular wiring.

The long-term overload of power transformer will slowly cause the scalding and insulation aging of solenoid coil, resulting in short circuit between coils, two-color short circuit or short circuit on the ground, resulting in the ignition of power transformer. Therefore, the insulation compressive strength of power transformer shall be tested before installation and operation and overload is not allowed in the whole process of operation.


SalfeldenDry type transformer ReportHow to perform a stress test



Oil leakage at looper flange

query.Outdoor sampling shall be carried out in sunny days or dry weather with low environmental humidity. During sampling,SalfeldenTemperature measurement of dry-type transformer,SalfeldenTechnical parameters of power transformer,SalfeldenOutline dimensions of 2500kVA dry type transformer, it is necessary to resolutely prevent the invasion of dirt such as rain, snow, wind and sand.

What is the cause of power transformer core failure?

Use fiber materials to seal the bolts to achieve the goal of controlling leakage. The other is to screw out the bolt (nut), wipe the Fushi blue film remover on the surface, and then tighten it after wiping the raw materials on the surface. After drying, the treatment goal can be achieved.

Salfelden.Oil leakage of cast iron parts

Dry type transformer factory

Power transformer is one of the key equipment in power station and substation. The function of power transformer is in all aspects. It can not only raise the voltage and send electromagnetic energy to the power consumption area, but also reduce the voltage to each application voltage, voltage transformation and blood pressure reduction must be carried out by the transformer.