SeattleLaboratory small lifting platformWhat are the basic components

announcer:hp60HP184127502 release time:2024-09-06 10:27:31

The electric lifting platform needs to work under load according to the regulations on the nameplate during use, but overloading is strictly prohibited during use. Especially in emergency situations, it can only briefly overload by 10%.

Suitable for 2-3 story steel structures or concrete workshops, both internal and external.

Seattle.Multiple modes. Of course lifting stage manufacturers can also increase their daily order volume by adding models during their business operations. Because different customers have different specific usage requirements, the applicable modes often vary. An appropriate increase model can attract more customers and achieve better results.

The functions of electric cargo elevators are very diverse, and many equipment designs are very complex. If ideal delivery requirements can be achieved during operation the sealing conditions, specific critical states and information need to be taken seriously. It is also crucial to understand the safety performance of these operations, Some security information is also very important, and it is important to pay attention to the characteristics of performance.

.Safe operation voltage; Select rolling guide shoes, with high accuracy, wear resistance, and smooth lifting.

When using an electric lifting platform, there are many details that need to be noted,SeattleFixed small elevator, such as placing it on a flat surface during use to prevent tipping during work. In addition, what are the precautions for using electric lifting platforms?

The working principle of the elevator is that hydraulic oil forms a certain pressure through a vane pump, explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil from the upper end of the hydraulic cylinder returns to the oil tank through an explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge.


SeattleLaboratory small lifting platformWhat are the basic components



The electric lifting platform needs to work under load according to the regulations on the nameplate during use, but overloading is strictly prohibited during use. Especially in emergency situations, it can only briefly overload by 10%.

However, in the process of use, the first step is to select and purchase according to the characteristics of the product. Among them, it is necessary to choose a small and simple electric lifting platform, as this type of lifting platform is convenient for installation and disassembly, making it particularly convenient to use. At the same time, its electrical system is very safe, and its appearance can be designed according to customer needs during use. Especially for its category, their weight range is generally below 400KG, and their speed should be set to a rated speed of 0.5m/s. During the startup process, manual buttons can be used and usually it can operate on its own within 3 seconds.

Select the elevator dedicated leveling permanent magnet switch, which has a good leveling effect.

How much is it.When using, the weight should be evenly distributed, mainly in the center of the countertop. However, for special cases, partial loading is allowed,SeattleSelf propelled small elevator, but the longitudinal load cannot exceed half of the rated load. The horizontal load should not exceed one-third of the rated load, so this detail needs to be noted during use.

Especially when its pipes are in use, they are quite boring and can roll, so in this case, it is not allowed to carry people during use, and it is strictly prohibited to carry people. If the electric lifting platform carries people during use, it is equipped with railings or anti crack valves, which are mainly used to prevent the oil pipe from breaking or causing its workbench to fail during use and then descend.

What is the difference between a self-propelled elevator and a self-propelled hydraulic elevator?


SeattleLaboratory small lifting platformWhat are the basic components



Any mechanical equipment has a certain working principle, and important components are very important when using a lifting platform. When making a selection, the lifting platform should be able to understand the specific working principle during use. When operating, it is formed by a vane pump with a certain pressure and can be operated through oil filter directional valves, throttle valves, etc, It can make its activity upward and lift heavy objects. During operation, the pressure can be adjusted, and a pressure gauge can also be used to observe some information.

The cost is reasonable.To understand the operation of the mechanism, timely troubleshooting is necessary to ensure the normal operation and use of the machine. During installation, it is necessary to disassemble or adjust the rotating mechanism. In this case, it is necessary to ensure that the rotating mechanism can be parallel to the centerline of the reducer and the centerline of the gear, and of course, the meshing clearance should also be appropriate. If this is not appropriate, then the machinery cannot operate normally.

If hydraulic elevators are used on campus, it can better enhance the safety and security of the campus. For campuses especially after school every day, there are a large number of parents and there are also safety hazards such as people and cars. Maintaining order in such situations is a good idea.

The fixed lifting platform has a very obvious advantage over other types of work platforms, which is that the work intensity is very high. After carrying out high-intensity work, people often use fixed lifting platforms for operation.

Seattle.Refueling the shaft and other parts with oil. The elevator cannot lift or the lifting force is weak. The pressure adjustment of the overflow valve does not meet the requirements. Adjust the pressure to the required value. Check for internal leakage in the oil cylinder or replace the oil cylinder component. Check for clamping or internal leakage of the reversing valve or replace the valve component. The oil level is too low, and the oil inlet filter is blocked. Add enough oil, Clean the oil filter, check if there is a problem with the oil supply pump,SeattleSmall fixed lifting platform, or replace the pump. The loosening device does not lift or the lifting force is weak. The pressure adjustment of the overflow valve does not meet the requirements. Adjust the pressure to the required value. If the oil cylinder leaks, check if the reversing valve is stuck or the internal oil leakage surface is too low. If the oil inlet filter is blocked, check if the oil supply pump is faulty. Check if the one-way valve core and valve seat are worn or damaged. Check if the one-way valve spring is fatigued or deformed, and if there is a problem with the heavy operating rod mechanism Adjust and replace unqualified parts; Clean the valve components; Check the cleanliness of the hydraulic oil valve core for clamping (manufacturing, installation issues, dirt issues)

When there is a power outage, manual emergency descent can be used, which is safe, convenient, fast, and practical.

And connectors. Beautiful appearance, easy operation, visual display of the position of the elevator car on the floor, wiring harness connected using connectors, with automatic and manual options.