by a riverIndoor hydraulic lifting platform carMaterial shielding mechanism

announcer:hp530HP141750488 release time:2024-07-05 17:19:21

Ensure that there is a suitable power supply at the installation site, and separate maintenance of the distribution box is required. The distribution box should have a leakage switch, and the hydraulic cargo elevator construction site should be equipped with a fire extinguisher to prevent welding operations from causing fires. When selecting a leakage switch, it should be suitable for the operating power.

Volume speed control circuit: Speed control is achieved by adjusting the displacement of a variable pump or variable motor.

by a river.The hook or rope of the seat belt should be hung on a sturdy and sturdy component or a steel wire rope specifically designed for hanging the seat belt. Prohibit hanging on moving or unstable objects.

A hydraulic elevator is a type of elevator equipment consisting of a walking mechanism, hydraulic mechanism, electric mechanism, and support mechanism. The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter explosion-proof electromagnetic directional valve, hydraulic control one-way valve throttle valve, and balance valve,by a riverElectric hydraulic fixed lifting platform, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge.

.Regularly check whether each organization is functioning properly and whether there is noise. If problems are found, they should be promptly cleaned up.

Pay attention to checking each steel wire rope for signs of broken wires and loose drums. If it exceeds the relevant rules, the hydraulic elevator may experience problems with the hydraulic pump,by a riverCustomized hydraulic lifting platform, motor, valve, and hydraulic installation after repairing the hydraulic system, which can easily cause vibration and generate significant noise.


by a riverIndoor hydraulic lifting platform carMaterial shielding mechanism



The elevator is evenly distributed at any position on the guide rail at 150% of the maximum load capacity, and should be stable at the maximum lifting height.

The manufacturer of hydraulic cargo elevators tells you the reason for the instability of hydraulic lifting equipment. Hangzhou hydraulic cargo elevator equipment has always had good stability, mainly used for heavy types of goods. However, during use,by a riverScissor fork hydraulic lifting table, Hangzhou hydraulic cargo elevators may inevitably encounter some faults during the lifting process, such as very unstable conditions. What is the reason for the instability of the elevator? How to solve these problems?

There is noise inside the hydraulic cylinder. When replacing the hydraulic oil, there was air in the hydraulic cylinder due to an operational error. Under high pressure, it is easy to generate cavitation and high-frequency noise. When the rod is bent or replaced with a new seal, the new seal is too tight, which can also produce significant noise. If it is a problem of tight sealing, it needs to be corrected. In addition, hydraulic pipelines should use hoses as much as possible, even when arranging pipelines, it can reduce vibration and noise, and the pipelines should avoid dead bends as much as possible.

Where can I find it?.There is noise inside the hydraulic cylinder. When replacing the hydraulic oil, there was air in the hydraulic cylinder due to an operational error. Under high pressure, it is easy to generate cavitation and high-frequency noise. When the rod is bent or replaced with a new seal, the new seal is too tight, which can also produce significant noise. If it is a problem of tight sealing, it needs to be corrected. In addition, even when arranging pipelines, it can reduce vibration and noise, and the pipelines should avoid dead bends as much as possible.

The elevator is evenly distributed at any position on the guide rail at 150% of the maximum load capacity, and should be stable at the maximum lifting height.

Do not use hydraulic lifting equipment with malfunctioning issues. The problem should be resolved before carrying cargo.


by a riverIndoor hydraulic lifting platform carMaterial shielding mechanism



A hydraulic elevator is a type of elevator equipment consisting of a walking mechanism, hydraulic mechanism, electric mechanism, and support mechanism. The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge.

Focus on Development.Stability: The workbench should evenly withstand 125% of the MAX load capacity and be stable at the MAX elevation.

Any work carried out at a height of 2 meters or above should be considered as work at height. Any work that can be done in advance on the ground must be done on the ground to minimize high-altitude operations.

When the hydraulic oil is insufficient, the hydraulic pump will experience suction, causing air to enter the hydraulic oil and producing high noise.

by a river.Therefore, in the hydraulic pipeline assembly line, it is necessary to avoid dead bends as much as possible and check the tightness of the sleeve in a timely manner.

Users should arrange dedicated personnel to operate hydraulic elevators, formulate usage details and safety precautions for hydraulic elevators based on their own situation, and hang them on the

Check valve leakage: If the natural wear of the check valve exceeds the specified value after long-term use, it will cause leakage. Disassemble and clean the check valve and replace it if necessary.